60 Watt, Efficient,
Compact Non-Dimmable CV Class 2 / Class II LED Drivers. Very high power density of 20 W/in3, Class 2 power supply, UL Class P, Lifetime: 50,000 hours min at 70° C case temperature, IP20-rated case with silicone-based potting, 90° C maximum case hot spot temperature.
FEATURES:
- Very high power density of 20 W/in3
- Class 2 power supply
- UL Class P
- IP20-rated case with silicone-based potting
- 90°C maximum case hot spot temperature
- Lifetime: 50,000 hours min at 70°C case temperature
- Complies with ENERGY STAR®, DLC (DesignLight Consortium®) and CA Title 24 technical requirements
- Additional safety approvals when using the optional strain reliefs for models with “-T” suffix
- Worldwide safety approvals
1
- EMC COMPLIANCE AND SAFETY APPROVALS
EMC Compliance
|
Conducted and Radiated EMI
|
VLMXXW models: Compliant with FCC
CFR Title 47 Part 15 Class B at 120
Vac & Class
A at 277 Vac
VLMXXE models:
EN55015 (CISPR 15) compliant
at 220, 230, and 240 Vac
|
Harmonic Current
Emissions
|
IEC61000-3-2
|
For Class C
equipment
|
Voltage Fluctuations
& Flicker
|
IEC61000-3-3
|
|
Immunity Compliance
|
ESD (Electrostatic Discharge)
|
IEC61000-4-2
|
6 kV contact discharge, 8 kV air discharge, level
3
|
RF Electromagnetic Field Susceptibility
|
IEC61000-4-3
|
3 V/m, 80 - 1000 MHz, 80% modulated at a distance of 3 meters
|
Electrical Fast Transient
|
IEC61000-4-4
|
± 2 kV on AC power
port for 1 minute,
±1 kV on signal/control lines
|
Surge
|
IEC61000-4-5
|
± 2 kV line to line (differential mode) /± 2 kV line
to common mode ground
|
ANSI/IEEE c62.41.1-2002 & c62.41.2-2002 category A, 2.5
kV ring wave
|
Conducted RF Disturbances
|
IEC61000-4-6
|
3V, 0.15-80 MHz, 80% modulated
|
Voltage Dips
|
IEC61000-4-11
|
>95% dip, 0.5 period; 30% dip, 25 periods;
95% reduction, 250 periods
|
|
Safety Agency Approvals
|
UL
|
VLMXXW models: UL8750
listed Class 2
|
cUL
|
VLMXXW models: CAN/CSA C22.2
No. 250.13-14 LED equipment for lighting applications
|
CE
|
VLMXXE models:
IEC61347-2-13 electronic control
gear for LED Modules &
EN55015 (EMC compliance)
|
CB
|
VLMXXE models
|
ENEC
|
VLMXXE models
|
Safety
|
|
Units
|
Minimum
|
Typical
|
Maximum
|
Notes
|
Hi Pot
(High Potential) or Dielectric voltage-withstand
- VLMXXW models
|
Vdc
|
2500
|
|
|
Insulation between the input
(AC line and Neutral) and the
output
Tested at the RMS voltage equivalent of 1768 Vac
|
- VLMXXE models
|
|
4242
|
|
|
Tested at the RMS voltage equivalent of 3000 Vac
Meets class II reinforced/double insulation
|
12 - MECHANICAL DETAILS
• Packaging Options: Aluminum case
•
I/O Connections:
.• Models with flying leads: 18 AWG on all leads, 203mm (8 in) long, 105°C rated, stranded, stripped by approximately and with “S” suffix 9.5 mm, and tinned. All the wires, on both input and output, have a 300 V insulation rating • Models with “T” suffix: Terminal blocks • Ingress Protection: IP20 rated •
Mounting Instructions: The VLM60/40 driver
case must be secured on a flat surface
through the two mounting tabs, shown here below in the case outline drawings. We recommended mounting the VLM60/40 on a baseplate with dimensions of 150 x 60 x 2 mm (5.91 x 2.36 x 0.08 in).
13
- OUTLINE DRAWINGS (VLMXXW MODELS WITH FLYING LEADS)
Dimensions: L 130.0 x W 19.65 x H 19.8 mm (L 5.12 x W 0.77 x H 0.78 in)
Weight: 119 g (4.20 oz)
|
|
|
|
|
|
|
|
|
|
|
|
|
Technical Data
1 - INPUT SPECIFICATION (@25°C ambient temperature)
|
Units
|
Minimum
|
Typical
|
Maximum
|
Notes
|
Input Voltage Range
(Vin)
- VLMXXW models
|
Vac
|
90
|
120 & 277
|
305
|
The rated output
voltage for each
model is achieved at Vin≥105 Vac &
at Vin≥249 Vac for VLMXXW
models, and at Vin≥209 Vac for VLMXXE models.
At maximum load,
as specified in section 1.
|
- VLMXXE models
|
|
198
|
230
|
264
|
Input Frequency Range
- VLMXXW models
|
Hz
|
47
|
60
|
63
|
|
- VLMXXE models
|
|
47
|
50
|
53
|
Input Current
(Iin)
|
A
|
|
|
0.7 A @ 120 Vac
0.4 A @ 230 vac
0.3 A @ 277 Vac
|
|
Max Units on a 16 A Circuit Breaker
|
|
VLM40: 38 (120 Vac), 71 (230 Vac), 88 (277 Vac) units
VLM60: 25 (120 Vac), 48 (230 Vac), 59 (277 Vac) units
|
The maximum number of units
allowed per 16 A circuit
breaker is based on
worst-case conditions at 100% output.
|
Power Factor (PF)
|
|
0.9
|
> 0.9
|
|
At nominal input voltage
From 100% to 60% of rated power
|
Inrush Current
|
A
|
Meets NEMA-410 requirements
|
At any point on the sine
wave and 25°C
|
Leakage Current
|
μA
|
|
|
400 μA @ 120 Vac
700 μA @ 230 Vac
920 μA @ 277 Vac
|
Measured per IEC60950-1
|
Input Harmonics
|
Complies with IEC61000-3-2 for Class C equipment
|
|
Total Harmonics Distortion (THD)
|
|
|
|
20%
|
At nominal input voltage
From 100% to 60% of rated power
Complies with DLC (Design Light Consortium) technical requirements
|
Efficiency
|
%
|
-
|
up to 90%
|
-
|
Measured with nominal input
voltage
|
Isolation
|
The AC input to the main DC output
is isolated.
|
2 - MAIN OUTPUT SPECIFICATION (@25°C
ambient temperature)
|
Units
|
Minimum
|
Typical
|
Maximum
|
Notes
|
Output Voltage (Vout)
|
Vdc
|
|
12, 24,
48
|
|
See ordering information for
details
|
Output Current (Iout)
|
A
|
|
|
12 Vdc: 5.0 A
24 Vdc: 2.5 A
48 Vdc: 1.25
A
|
The rated output voltage for each model is achieved at Vin≥105 Vac & at Vin≥249 Vac for VLMXXW models,
and at Vin≥209 Vac for VLMXXE
models.
|
Output Voltage
Regulation
|
%
|
-5
|
|
5
|
At nominal AC line voltage
Includes load and current
set point variations.
|
Output Voltage Overshoot
|
%
|
-
|
-
|
10
|
The driver
does not operate outside
of the regulation requirements for more than
500 ms during power on with maximum load.
|
Ripple Voltage
|
≤ 5% of rated output voltage
for each model
|
Measured at maximum load and nominal
input voltage
Calculated
in accordance with
the IES Lighting Handbook, 9th edition
|
Start-up Time
|
ms
|
|
|
500
|
Measured from application of AC line
voltage to 100%
light output
Complies with California Title 24 and ENERGY STAR® luminaire specification.
|
3 - ENVIRONMENTAL CONDITIONS
|
Units
|
Minimum
|
Typical
|
Maximum
|
Notes
|
Operating Ambient Temperature (Ta)
|
°C
|
-20
|
|
50
|
50°C is the non-derated temperature (Refer to section 7 "Output
power de-rating at higher temperatures".
|
Maximum Case Temperature (Tc)
|
°C
|
|
|
+90
|
Case temperature measured at the
hot spot tc (see
label in page 13)
|
Storage Temperature
|
°C
|
-40
|
|
+85
|
|
Humidity
|
%
|
5
|
-
|
95
|
Non-condensing
|
Cooling
|
Convection cooled
|
|
Acoustic Noise
|
dBA
|
|
|
22
|
Measured at a distance
of 1 foot (30 cm)
|
Mechanical Shock Protection
|
per EN60068-2-27
|
|
Vibration Protection
|
per EN60068-2-6 & EN60068-2-64
|
|
|
MTBF
|
> 200,000 hours when operated
at nominal input and output conditions, and at Tc ≤ 70°C
|
Lifetime
|
50,000 hours at Tc ≤ 70°C
maximum case hot spot
temperature (see hot spot tc on label
in page 13)
|
|
|
|
|
|
|
|